title: "IBC inspection and test date checker"
url: https://fortitude21.com/ibc-inspection-date-checker
language: en
description: "Paste an IBC’s UN mark and plate dates to see when its leak test and 2.5 and 5-year inspections fall due and the last month it may be filled."
---

# IBC inspection and test date checker

Paste the mark off a caged tote or a plastic IBC, add the dates from its plate, and see when each test falls due and the last month it may be filled.

## About this checker

### What it works out

When an IBC’s next leakproofness test and its next 2.5 and 5-year inspections fall due, when its five-year life for dangerous goods ends, and so the last month it may be filled. It reads the month and year of manufacture straight from a pasted UN mark.

### Who uses it

Site and warehouse managers keeping a fleet of [caged tote](https://fortitude21.com/ibc-tote-guide)s in date, dangerous goods safety advisers checking a customer’s IBCs, and buyers deciding whether to retest, rebottle or replace.

### What it assumes

- The rules of the UN Model Regulations and ADR, or US 49 CFR if you pick it. Paragraph numbers are shown beside each date.
- Plate dates give month and year only, so the first day of the due month counts as the deadline.
- The 2.5-year clock runs from the last inspection of either level; the 5-year clock from manufacture, a repair or the last 5-year inspection.

### Where it stops

- It reads the dates you enter; it cannot see the IBC. A failed inspection, damage or a missing plate overrides any date here.
- A competent authority can approve a longer life for a design, and some substances set a shorter one. The two in the menu are the common cases.

**Products behind the numbers:** [IBC spill pallets](https://fortitude21.com/product-ibc-spill-pallets), [Industrial & Chemical Containers](https://fortitude21.com/industrial-and-chemical).

## The dates an IBC runs on

Metal, rigid plastic and composite IBCs carry dangerous goods on a cycle of 2.5 and 5-year tests. Under the UN and ADR rules, plastic and composite IBCs also stop at five years.

| Check | When | Applies to | Paragraph |
| --- | --- | --- | --- |
| Leakproofness test | Before first use, then at most every 2.5 years | IBCs for liquids (31) and for solids filled or emptied under pressure (21) | 6.5.4.4.2 |
| Inspection of the outside and service equipment | At most every 2.5 years | Metal, rigid plastic and composite IBCs | 6.5.4.4.1 (b) |
| Full inspection, marks and inside included | Before service, then at most every 5 years | Metal, rigid plastic and composite IBCs | 6.5.4.4.1 (a) |
| End of use for dangerous goods | 5 years from manufacture; for a composite, of the inner receptacle | Rigid plastic and composite IBCs, under the UN and ADR rules | 4.1.1.15 |

*Under US rules the five-year end of use does not apply; the 2.5 and 5-year tests do.*

## Where the dates are on the IBC

The month and year of manufacture is the third part of the UN mark: an IBC marked `31HA1/Y/02 26/...` was made in February 2026. The plate beside the mark carries the date of the last leakproofness test and the date of the last inspection, as month and year. A composite IBC’s inner receptacle carries its own month and year, which sets its five-year life and can differ from the main mark.

The plate does not say whether the last inspection was the 2.5 or the 5-year level. Leave the level at “not sure” and the checker counts the five years from manufacture or the last repair, which gives the earliest date.

## After the due date

- An IBC may not be filled once its test or inspection date has passed.
- One filled before that date may travel for up to three months after it.
- An empty IBC that has not been cleaned may travel to its inspection, and one past its date may carry goods back for disposal for up to six months, with a statement on the transport document.
- The text gives the five-year life no grace period, so the checker treats it as a hard stop.

These come from 4.1.2.2. US rules let an IBC filled before its due date travel without a time limit.

## A new inner receptacle restarts the clock

Replacing the inner receptacle of a composite IBC with one of the original design from the same maker counts as a repair. The tests after the repair stand in for the 2.5 and 5-year tests, so both inspection clocks restart at the repair date, and the five-year life restarts at the new receptacle’s date. A receptacle of another design or maker makes it a remanufactured IBC, with a new mark and a new date of manufacture.

## The United States counts differently

| Point | UN and ADR | US, 49 CFR |
| --- | --- | --- |
| Five-year life for plastic and composite IBCs | Yes (4.1.1.15) | No |
| IBC filled before the due date | May travel up to three months after it | No time limit stated (180.352(a)) |
| Start of the 2.5-year clock | Not stated: at most 2.5 years between tests | Manufacture or a repair |
| Window to test early or late | None | None |

## Worked examples

| IBC | Dates on it | Next 2.5-year test | Next 5-year inspection | End of use |
| --- | --- | --- | --- | --- |
| Composite tote, no later tests | 31HA1, made 03/2024 | 09/2026 | 03/2029 | 03/2029 |
| Same tote, tested 09/2026 | 31HA1, made 03/2024, leak test and inspection 09/2026 | 03/2029 | 03/2029 | 03/2029 |
| Rebottled tote | 31HA1, made 01/2021, new inner receptacle 05/2025 fitted 06/2025 | 12/2027 | 06/2030 | 05/2030 |
| Metal IBC | 31A, made 04/2019, 5-year inspection and leak test 04/2024 | 10/2026 | 04/2029 | None |

## Common questions

### How often must an IBC be inspected?

Every 2.5 years on the outside and its service equipment, and every 5 years in full, including its marks and the inside. IBCs for liquids, and for solids filled or emptied under pressure, also take a leakproofness test at least every 2.5 years.

### How long can a plastic IBC be used?

Under the UN and ADR rules, five years from its date of manufacture; for a caged composite IBC, from the date on its inner receptacle. Some substances set a shorter period: two years for nitric acid over 55 per cent. US rules set no five-year limit.

### Can you fill an IBC after its test date?

No. An IBC may not be filled once its test or inspection date has passed. One filled before the date may travel for up to three months after it under the UN and ADR rules.

### Is there a window for the 2.5-year test?

No. Unlike tanks, IBCs get no three-month window either side of the date. A test done early sets the next date from the day it was done.

## References

The standards and regulations this page relies on, at their issuing body. Where a market rule is named here, check the current revision before you specify against it.

- [UN Model Regulations on the Transport of Dangerous Goods (Rev. 24)](https://unece.org/transport/dangerous-goods/un-model-regulations-rev-24)
- [RID 2025, consolidated text from OTIF; chapters 4.1 and 6.5 are shared word for word with ADR](https://otif.org/fileadmin/docs/LegalTexts/COTIF/DangerousGoodsRID/RID/RID_2025_e_1_November_2024.pdf)
- [ADR: Agreement concerning the International Carriage of Dangerous Goods by Road (UNECE)](https://unece.org/about-adr)
- [49 CFR 180.352: retest and inspection of IBCs (US)](https://www.ecfr.gov/current/title-49/section-180.352)

Page updated 31 October 2026