Fortitude21
Home  /  Calculators  /  Jerry can sizing calculator

Jerry can sizing calculator

Work out how much water or fuel you need to hold and how many jerry cans that takes. Water is sized against a published humanitarian standard. Fuel is sized by distance or by running hours, depending on what you operate.

What are you sizing?

Water sizing

Units

%

Your requirement

4,125× 20L Stainless Steel Water Can
82,500 L21,794 US gal to hold
1,032cartons at 4 per carton
How the quantity is worked out500people10days×15.0L/person/day×= 75,000 L + 10% margin = 82,500 LNeededMarginSpare space1 icon = 100 cansdashed icon = 25 cansContainers this order fills20ft852 cans each4.840HQ2,000 cans each2.1
Basis500 people × 10 days × 15.0 L/person/day
Before margin75,000 L
Contingency10% (7,500 L)
Actually held82,500 L in 4,125 full cans
Container load4.8 × 20ft container or 2.1 × 40ft HQ

Every default above is either a published standard, named where it is used, or a planning margin you can change. Nothing here is a quotation. Carton and container figures appear only for products where the factory has given us real dimensions; everything else says so.

About this calculator

What it works out

How many litres of water or fuel you need to hold, and how many jerry cans, cartons and containers that comes to. Water starts from people, days and a rate per person per day. Fuel starts from distance and consumption for vehicles, or from running hours and burn rate for boats, generators and machinery.

Who uses it

Relief agencies and emergency planners stocking water, fleet and overland operators carrying fuel past the last pump, site managers sizing generator autonomy, and buyers turning a requirement into an order quantity.

What it assumes

  • Water rates from the Sphere Handbook (2018): 15 litres per person per day by default, 7.5 for a short acute phase, 50 in an urban setting and 3 for drinking only. You can enter your own.
  • A 10 per cent margin on water and a planning reserve on fuel: 10 per cent for road, 25 overland, 20 for generators, 15 for machinery and 50 for boats, the one-third rule. Each is shown and you can change it.
  • Cans counted at their nominal capacity and rounded up. Carton and container figures come from our factory loading tables.

Where it stops

  • It sizes quantity, not compliance. Storage and carriage limits still apply: in Great Britain a portable petrol container may hold no more than 10 litres in plastic or 20 in metal.
  • The consumption figure is yours. A generator burns to its load, so take the rate from the set’s plate at the load you run.
  • It does not size the store’s containment. The spill pallet calculator does that.

Products behind the numbers: Fuel & Gas Cans, Water & Food-Grade Jerry Cans, NATO & Military Jerry Cans.

Worked examples

Each row runs the calculator's own defaults: the Sphere rates for water, the planning margins the tool shows for fuel, and the first can it suggests for that use. The last column is the share of a 20ft container the order fills, from that can's loading figure.

ScenarioThe sumMarginTo holdCans20ft containers
Relief camp: 500 people for 10 days 500 × 10 days × 15 L 10% 82,500 L 4,125 × 20 L 4.8
Acute response: 1,000 people for 3 days 1,000 × 3 days × 7.5 L 10% 24,750 L 1,238 × 20 L 1.5
Overland: 500 km out and back 500 km × 2 × 13 L/100 km 25% 163 L 9 × 20 L 1%
Generator: 72 hours of backup 72 h × 4.5 L/h 20% 389 L 20 × 20 L —
Boat: 12 hours underway 12 h × 4.5 L/h 50% 81 L 5 × 20 L 1%
Litres per 20ft container Litres of fuel a 20ft container carries in each size of NATO-pattern can: more small cans fit, but less liquid. LITRES PER 20FT CONTAINER 3 L compact can 9,000 L 10 L NATO can 13,680 L 20 L NATO can 17,040 L 25 L NATO can 16,300 L 30 L NATO can 16,440 L
Small cans ship more units and less liquid. When the container is the cost, compare the litres it carries rather than the can count.

How the sums work

Water and fuel finish the same way: a quantity, a margin, then cans. They differ in where the quantity comes from. Water starts from people and days at a published rate. Fuel starts from distance or from engine hours, depending on what burns it.

Sizing water, step by stepPeople times days times litres a day, plus a margin, divided by the can size. People
100 in this example
Days
7 days of supply
Per day
15 litres each, the Sphere minimum
Margin
10 per cent on top
Cans
578 of 20 litres
100 × 7 × 15 is 10,500 litres. The margin takes it to 11,550, and the can size turns that into a count.
Litres per person a day Sphere Handbook water rates: survival intake, a short acute drought, the minimum standard and an urban, middle-income setting. LITRES PER PERSON A DAY Drinking only 3 L Acute drought 7.5 L Minimum standard 15 L Urban, middle-income 50 L
Sphere Handbook, 2018. The acute rate is for a short spell only, and drinking water alone covers no cooking or washing.
Distance or hoursWhich fuel uses the calculator sizes by distance and which by running hours. By distance By hours Road and trucking Road and trucking: suitable for By distance✓ Road and trucking: not suitable for By hours✕ Overland and 4x4 Overland and 4x4: suitable for By distance✓ Overland and 4x4: not suitable for By hours✕ Boats Boats: not suitable for By distance✕ Boats: suitable for By hours✓ Generators Generators: not suitable for By distance✕ Generators: suitable for By hours✓ Farm machinery Farm machinery: not suitable for By distance✕ Farm machinery: suitable for By hours✓
An engine that runs while the vehicle stands still burns by the hour, so a boat, a generator or a tractor is sized from running time.
The one-third rule Twelve hours underway at 4.5 litres an hour: 27 litres out, 27 back and 27 in reserve. THE ONE-THIRD RULE A third out 27 L A third back 27 L A third in reserve 27 L To carry 81 L
The calculator takes the running hours you enter as out and back, then adds half as much again as the untouched third: 5 cans of 20 litres here.

Household water by country

Pick a country under “Your scenario” and the calculator loads that government’s advice for a household of four. Change the people for a school, a care home or a whole municipality; the rate and the days stay as the government sets them.

CountryPer person a dayDaysPer person20 L cans, household of fourCalculator
Netherlands3 L39 L2Open
Sweden3 L721 L5Open
Norway2.86 L720 L5Open
Finland2 L36 L2Open
Denmark3 L39 L2Open
Germany2 L1020 L5Open

Read from each official page on 5 October 2026. Norway gives a weekly total of 20 litres, so its daily rate is 20 divided by 7. The can count includes the calculator’s 10 per cent margin.

Water each government asks a household to hold Litres per person under each country preset in the calculator. WATER EACH GOVERNMENT ASKS A HOUSEHOLD TO HOLD Netherlands 9 L Sweden 21 L Norway 20 L Finland 6 L Denmark 9 L Germany 20 L
Litres per person over the days each government advises. Sweden, Norway and Germany plan for a week or more; the Netherlands, Finland and Denmark for three days.

Generator fuel from the kVA rating

If you know the generator’s size but not its burn rate, choose “Generators & backup power”, enter the kVA and the average load, and the calculator fills the burn rate. The estimate comes from a straight-line fit to Cummins diesel data sheets from 17 to 500 kVA, which it matches within about 6 per cent on average. Your own set’s plate figure is better where you have it.

Diesel set50% load75% loadFull load20 L cans for 72 h at 75%
20 kVA3.2 L/h4.3 L/h5.3 L/h19
50 kVA6.6 L/h9.2 L/h11.8 L/h40
100 kVA12.2 L/h17.4 L/h22.6 L/h76
200 kVA23.4 L/h33.8 L/h44.2 L/h147

Litres per hour = 1.0 + kVA × (0.008 + 0.208 × load), at a power factor of 0.8. The can count adds the calculator’s 20 per cent generator margin.

Diesel burn at 75 per cent load Estimated litres per hour for 20, 50, 100 and 200 kVA diesel generator sets at 75 per cent load. DIESEL BURN AT 75 PER CENT LOAD 20 kVA 4.3 L/h 50 kVA 9.2 L/h 100 kVA 17.4 L/h 200 kVA 33.8 L/h
From a straight-line fit to Cummins data sheets. Your set’s own figure is better.

What each market requires

The calculator shows the checklist for the market you pick. Every market is below: first the rules that apply wherever the cans go, then each market's own layer, for water cans and for fuel cans. Each line is what the market requires to admit the product, not what Fortitude21 holds.

Applies wherever you ship

Water cans

RequirementStatusWhat it coversYou need
Not a dangerous goodWorth knowingPotable water carries no UN packaging certification, no ADR, no IMDG and no IATA dangerous-goods paperwork.Nothing. This is the reason the water line is cheaper and faster to place in a new market than the fuel line.
Declaration of ComplianceRequiredA food-contact DoC from the manufacturing site, naming the grade and the finish.Issued by the factory, per SKU, per plant.
Migration testing — the whole wetted pathRequiredThe steel body is rarely the problem. The gasket, cap liner, spout and tap are plastic and elastomer, and they are what fails a food-grade claim.A migration test report covering every part the water touches, not just the shell.

Fuel cans

RequirementStatusWhat it coversYou need
UN packaging certification — 3A1 / 3B1 / 3H1RequiredSteel non-removable head is 3A1, aluminium 3B1, plastic 3H1. Maximum 60 litres, and an opening on a non-removable head cannot exceed 7 cm.A competent-authority approval and the full mark string, e.g. UN 3A1/Y1.4/150/26/…
The test programme behind that markWorth knowingDrop, stack, leakproofness and hydraulic testing. Metal needs 24 hours of stack testing. Leakproofness runs three samples per design type, submerged under air pressure for at least five minutes.Roughly 13 cans are destroyed per design type. This is why the mark is not a formality and cannot be bought quickly.
Each plant must be coveredRequiredA UN approval is granted per design type, and the competent authority decides what a second plant must show before it may apply the mark. Germany’s BAM tests and codes each production site.Dual sourcing from Vietnam and China needs the approval to cover both plants. Ask both factories which certificate covers them.
Modal transport rulesRequiredADR for road, RID for rail, IMDG for sea, IATA DGR for air, 49 CFR in the United States.A dangerous-goods declaration per shipment, and a correctly marked package.

Each market on top of that

European Union

Water cans

RequirementStatusWhat it coversYou need
Regulation (EC) 1935/2004RequiredThe food-contact framework. It covers metals, but there are NO harmonised EU rules for metals and alloys, so the detail sits in national law and a single "EU compliant" claim means little.DoC plus migration report, then check the destination state. France requires stainless to contain at least 13% chromium.
Regulation (EU) 10/2011RequiredPlastics. This is the one that catches metal cans, because it governs the gasket, cap liner, spout and tap.A separate DoC for each plastic and elastomer component.
Regulation (EU) 2023/2006RequiredGood Manufacturing Practice at the production site.Factory GMP evidence.
Regulation (EU) 2023/988 (GPSR)RequiredGeneral Product Safety Regulation, in force since December 2024.An EU-based Responsible Person, traceability marking, and instructions in the destination language.
REACHIf it appliesSubstances of very high concern in coatings and elastomers.An SVHC declaration if any component exceeds threshold.

Fuel cans

RequirementStatusWhat it coversYou need
ADR approval and UN markRequiredRoad carriage of dangerous goods across the EU.Competent-authority approval and the mark on every can.
There is no CE marking for jerry cansWorth knowingNo EU directive covers them, so no CE mark exists to apply.Do not claim CE. Suppliers who do are signalling they have not read the framework.
Regulation (EU) 2023/988 (GPSR)RequiredGeneral Product Safety Regulation.EU Responsible Person, traceability, instructions.
DIN 7274Worth knowingThe classic German jerry can standard is dimensional, not a safety approval.Useful for buyer confidence about fit. It certifies nothing about containment.
United Kingdom

Water cans

RequirementStatusWhat it coversYou need
Retained food-contact lawRequiredGB retains the 1935/2004 and 10/2011 equivalents. Northern Ireland continues to follow EU rules, so the two can diverge.DoC and migration report; confirm which of GB or NI you are shipping to.
General Product Safety Regulations 2005RequiredUK general safety duty.Traceability and instructions.

Fuel cans

RequirementStatusWhat it coversYou need
UN mark, administered by VCA-DGORequiredThe UK competent authority for UN packaging approvals.Test report and application to VCA-DGO, or recognition of an existing approval.
Carriage of Dangerous Goods RegulationsRequiredUK road transport rules.Correct marking and a DG declaration.
United States

Water cans

RequirementStatusWhat it coversYou need
FDA 21 CFR 174–178RequiredFood-contact clearance for coatings, gaskets and liners. Stainless itself is generally accepted; the soft parts are the exposure.Component-level clearance evidence from the factory.
NSF/ANSI 51If it appliesFood equipment materials. Voluntary, but institutional and government buyers ask for it by name.Certification if your buyer specifies it.
California Proposition 65If it appliesApplies if any listed substance is present.An assessment, and a warning label if triggered.

Fuel cans

RequirementStatusWhat it coversYou need
EPA 40 CFR 59 Subpart FRequiredEvaporative emissions. Binds manufacturers AND importers. Scope is containers "designed and marketed or otherwise intended for use by consumers", and 0.25 to 10 US gallons, so a 20L can is inside it.A certificate of conformity. Import under someone else’s and you are jointly liable; EPA can demand a bond up to $5 per container. Records kept 5 years.
CPSC 16 CFR 1461 — flame mitigation deviceRequiredA flame arrester in the neck. ASTM F3326-21 for containers sold empty, ASTM F3429/F3429M-24 for pre-filled.A design change, not a certificate. A standard NATO can has no arrester.
CPSC 16 CFR 1460 — child-resistant closureRequiredASTM F2517-22e1, for petrol, kerosene and diesel containers up to 8.45 gallons (32 L).A compliant closure design plus test evidence.
General Certificate of ConformityRequiredAccompanies each shipment of a consumer product.Issued by the importer against test results.
ROUTE: UL 30 or FM listing as an OSHA safety canAlternative routeA container approved as a safety can under 29 CFR 1926.150–152 is EXCLUDED from EPA Subpart F, and CARB exempts OSHA and DOT safety cans.Flash-arresting screen, spring-closing lid, spout cover, and listing by a nationally recognised lab. Different cost, not a free pass. But it is one listing instead of four certifications, and it is what defence, airfield and industrial buyers actually ask for.
United States — California

California adds a layer the rest of the US does not, and most national distributors will not stock a SKU they cannot ship 50-state.

Water cans

RequirementStatusWhat it coversYou need
Proposition 65If it appliesAssessment and warning if a listed substance is present.Substance review of coatings and elastomers.

Fuel cans

RequirementStatusWhat it coversYou need
CARB Executive Order — 13 CCR 2467.2RequiredCertifies the container AND spout as one system. Unlike the federal rules there is NO consumer-scope limit: it binds manufacturers, importers and wholesale distributors alike.An Executive Order, plus the EO number and month/year of manufacture labelled on every can.
CARB performance standardsRequiredDiurnal emissions no more than 0.3 g/gal/day for containers made since 2009 (CP-501), automatic shut-off before overflow, self-closing and sealing on removal.Emissions and spout testing at a CARB-recognised lab.
An EO is not transferableWorth knowingIt belongs to the certifying manufacturer. You can sell the certified configuration, unmodified, under their EO. Change the spout, cap, neck or capacity and cover is broken.If you private-label, confirm with CARB in writing whether your brand can be added under CP-501 before printing anything.
Australia & New Zealand

Water cans

RequirementStatusWhat it coversYou need
Food Standards Code / AS 2070RequiredPlastics in contact with food.Compliance evidence for the soft components.
ACCC general safety provisionsRequiredAustralian Consumer Law.Traceability and accurate labelling.

Fuel cans

RequirementStatusWhat it coversYou need
AS/NZS 2906 — MANDATORYRequiredFuel containers. This is a mandatory consumer product safety standard, not a voluntary one. Australia enforces it.Certification to AS/NZS 2906 before any fuel can is offered for sale.
Canada

Water cans

RequirementStatusWhat it coversYou need
Food and Drugs Act, Division 23RequiredFood packaging materials.Compliance evidence; buyers sometimes ask for a CFIA letter of no objection.

Fuel cans

RequirementStatusWhat it coversYou need
Consumer Chemicals and Containers Regulations, 2001RequiredThe Canadian consumer container regime.CCCR compliance evidence.
Transportation of Dangerous Goods RegulationsRequiredCanadian TDG rules.UN mark and DG declaration.
China

Water cans

RequirementStatusWhat it coversYou need
GB 4806.9 (metals) and GB 4806.11 (rubber)RequiredNational food-contact standards for metal and elastomer components.Test report to the GB 31604 migration methods.
GB 4806.1RequiredGeneral safety requirements for food-contact materials.Compliance evidence.

Fuel cans

RequirementStatusWhat it coversYou need
CCC and export inspectionIf it appliesJerry cans are not on the CCC catalogue, but dangerous-goods export packaging is subject to inspection by the customs authority at the port of loading.An export packaging performance certificate from the manufacturing site.
GCC — Gulf states

Saudi Arabia, UAE, Kuwait, Qatar, Bahrain and Oman run a shared conformity system, so one route covers the bloc. Saudi then adds its own layer on top.

Water cans

RequirementStatusWhat it coversYou need
G-Mark (Gulf Conformity Mark)RequiredMandatory for regulated products across the GCC. It is a conformity mark for health, safety and environment, not a quality mark.A technical file (test reports, risk assessment, design specification) and a Certificate of Conformity from an approved body.
Arabic labellingRequiredLabels must be Arabic or bilingual Arabic/English, and applied BEFORE import. Food-contact containers must carry material type, capacity, a food-grade statement and directions for use.Correct artwork on the can at the factory, not relabelled on arrival.
SABER registration (Saudi Arabia only)If it appliesEvery product entering Saudi Arabia registers on the SABER platform, and all conformity certificates issue electronically through it.A Conformity Assessment Body engaged first, then a product certificate, then a shipment certificate per consignment.

Fuel cans

RequirementStatusWhat it coversYou need
G-Mark (Gulf Conformity Mark)RequiredSame route as above, against the relevant GSO standard for the product.Technical file plus Certificate of Conformity from an approved body.
SABER shipment certificate (Saudi Arabia only)If it appliesA product certificate is not enough. Each consignment needs its own shipment certificate, verified by the CAB that tested the product.Budget the per-shipment step into lead time, not just the one-off certification.
Arabic labellingRequiredApplied before import, including any warning statements.Factory-applied artwork.
Japan

Your jerry can plan already treats Japan as partner-led rather than direct, and the compliance picture supports that: both regimes reward a local partner who can front the paperwork.

Water cans

RequirementStatusWhat it coversYou need
Food Sanitation Act — Positive ListRequiredAct No. 46 of 2018, in force since 1 June 2020. Synthetic resins are PROHIBITED BY DEFAULT and permitted only if the substance appears on the Positive List. The five-year transition ended 31 May 2025, so it now applies in full.Confirmation that every resin in the gasket, cap liner, spout and tap is listed. The steel body is not the issue; the soft parts are.

Fuel cans

RequirementStatusWhat it coversYou need
Fire Service Act (消防法)RequiredJapan regulates hazardous-material containers under the Fire Service Act, and controls on portable petrol containers tightened after 2019.Confirm the current container approval route with a Japanese partner or JETRO before quoting. We have not verified the specific article that applies to an imported can, and we will not guess at it.
India

Water cans

RequirementStatusWhat it coversYou need
FSSAI Packaging Regulations 2018RequiredFood-contact packaging must be food grade and meet the applicable Indian Standard.Compliance evidence against the relevant IS specification.
BIS markingRequiredBureau of Indian Standards certification for the material specification.BIS licence and the mark on the product.

Fuel cans

RequirementStatusWhat it coversYou need
PESO approvalRequiredThe Petroleum and Explosives Safety Organisation approves containers for petroleum products. Only PESO-approved cans may be used by oil companies for retail of petroleum products.PESO container approval for the specific design. Buyers ask for it by name.
Southeast Asia (ASEAN)

There is no single ASEAN regime. Each member state regulates separately, so this is the layer we confirm per destination country.

Water cans

RequirementStatusWhat it coversYou need
Singapore — Food RegulationsIf it appliesThe Singapore Food Agency regulates food-contact articles under the Sale of Food Act and its Food Regulations.Food-contact evidence for the wetted path. Our Singapore base makes this the easiest market to document.
Per-country confirmationWorth knowingMalaysia, Thailand, Indonesia, Vietnam and the Philippines each run their own food-contact rules and import licensing.Name the destination country and we will confirm what sits on top of the universal items.

Fuel cans

RequirementStatusWhat it coversYou need
Singapore — SCDF licensingIf it appliesStorage and handling of petroleum and flammable materials is licensed by the Singapore Civil Defence Force. That is a duty on your buyer, not on the can, but it shapes what they can hold.Worth raising with a distributor early; it affects their order size.
Per-country confirmationWorth knowingImport controls on fuel containers vary sharply across ASEAN.Name the destination country and we will confirm.
Rest of Asia

Covers South Korea, Taiwan, Central Asia and the rest of the region. No shared regime, so the universal items are the reliable part.

Water cans

RequirementStatusWhat it coversYou need
Per-country food-contact rulesWorth knowingSouth Korea (MFDS Food Code) and Taiwan (TFDA) each operate their own food-contact standards with their own test methods.Tell us the country and we will confirm before you commit to a specification.

Fuel cans

RequirementStatusWhat it coversYou need
Per-country rules on top of the UN markWorth knowingThe UN packaging mark travels; national fuel-container rules do not.Name the destination and we will research it rather than assume the UN mark is sufficient.
Africa

Several African markets run pre-shipment conformity programmes, which means the goods are inspected BEFORE they leave, not on arrival. Missing that step strands a container at the destination port.

Water cans

RequirementStatusWhat it coversYou need
Pre-export verification of conformity (PVoC)If it appliesKenya (KEBS) and Nigeria (SONCAP) among others require conformity assessment before shipment, with a certificate presented at customs.An appointed inspection body engaged before the container is sealed. Confirm the destination country requires it. Not all do.

Fuel cans

RequirementStatusWhat it coversYou need
Pre-export verification of conformity (PVoC)If it appliesSame programmes, and dangerous goods draw closer scrutiny.Inspection booked pre-shipment, plus the UN mark.
Latin America

Mercosur harmonises some food-contact rules across Brazil, Argentina, Uruguay and Paraguay; the rest of the region does not.

Water cans

RequirementStatusWhat it coversYou need
Mercosur GMC food-contact resolutionsIf it appliesThe Mercosur bloc operates harmonised food-contact resolutions adopted into each member state law.Compliance evidence against the resolution the destination has adopted. Brazil additionally routes some products through INMETRO.

Fuel cans

RequirementStatusWhat it coversYou need
Per-country rules on top of the UN markWorth knowingFuel container rules are national, not harmonised.Name the destination and we will confirm.

This is a starting checklist compiled from the regulations it names, not legal advice, and rules change. Ask us which certificates we hold for a design and you will get a certificate number or a plain answer that we do not hold it yet.

Put this tool on your site

Safety advisers, trainers and trade bodies can embed it free. Paste the code into any web page. The tool updates when we update the rules, and the credit line links back here. Building software instead? The same answer comes as JSON from our free API.

Link to it or cite it

For a resource list, a training handout or a report: copy the link, or the citation.

Common questions

How many 20 litre jerry cans do I need for emergency water?

Multiply the people by the days and by the litres each person needs a day, add a margin, then divide by the can size. The Sphere Handbook minimum is 15 litres per person per day for drinking, cooking and hygiene, so 100 people for 7 days need 10,500 litres, or 578 cans of 20 litres with a 10 per cent margin.

How much fuel should I store for a generator?

Take the burn rate at your working load from the set's plate, multiply it by the hours you must run without a delivery, and add a margin. A set burning 4.5 litres an hour for 72 hours needs 324 litres, 389 with a 20 per cent margin: 20 cans of 20 litres.

How many jerry cans fit in a 20ft container?

It depends on the can. The standard 20-litre steel NATO fuel can loads 852 to a 20ft container and 2,016 to a 40ft high cube. Across our range a 20ft takes from 548 to 3,000 cans, fewer for the large cans and more for the small ones.

How much fuel should a boat carry?

Follow the one-third rule: a third to go out, a third to come back and a third in reserve. Size the running fuel from engine hours and add 50 per cent, which is the reserve third. Twelve hours at 4.5 litres an hour is 54 litres of running fuel and 81 litres to carry: 5 cans of 20 litres.

References

The standards and regulations this page relies on, at their issuing body. Where a market rule is named here, check the current revision before you specify against it.

Where The Water Figures Come From

The standard behind the number

Sphere Handbook, 2018

The water rates in this tool are the headline figures from the Sphere Handbook's minimum standards in water supply, sanitation and hygiene promotion. They are 15 litres per person per day for drinking, cooking and hygiene, 7.5 litres for a short time in the acute phase of a drought, and 50 litres as the minimum in an urban, middle-income setting. Survival intake alone is 2.5–3 litres.

Sphere Handbook →

Why fuel has two sums

A truck burns fuel over distance. A boat, a generator and a tractor burn it over time, because the engine runs whether or not you are covering ground. Sizing a vessel's fuel from a distance figure is a common and expensive mistake, so the tool changes its inputs to match what you operate rather than asking everyone for kilometres.

Marine defaults to a 50% reserve, which is the one-third rule: a third out, a third back, a third untouched.

Page updated

Turn that number into a quotation

The calculator gives you a quantity. We will give you a specification sheet, a carton and container breakdown, and a price at your volume.

Chat on WhatsApp